Technology πŸ‘€ KP Expert πŸ“… Oct 12, 2026 πŸ‘οΈ 593 views

How to Configure SNMP on Oracle Exadata: Step-by-Step Guide for Monitoring and Alerts

Send Exadata storage cell and database server alerts to your monitoring tool β€” subscribers, notifications, SNMPv3, testing and the mistakes that silently break it.
162
Default UDP port for SNMP traps
2
CLIs to configure: CellCLI and DBMCLI
v3
Recommended SNMP version for production

SNMP lets your Exadata storage cells and database servers push alerts to your monitoring system the moment something goes wrong, so you hear about a failing disk or a hot fan before users feel it.

Out of the box, Exadata does not send these alerts anywhere. Until you tell each component where to send its traps, problems are only visible to someone who logs in and looks.

In this guide, you will learn:

  • What SNMP does on Exadata and which components send traps
  • The prerequisites to check before you start
  • How to configure SNMP on storage cells with CellCLI and on database servers with DBMCLI
  • How to secure it with SNMPv3 and verify it with a test trap
  • Common problems, their fixes, and best practices to keep alerts flowing
Version note: The commands below work on recent Exadata System Software releases. Syntax can change between versions, so confirm them against the documentation for your release.
What SNMP Does on Exadata

On Exadata, SNMP is mainly used to send traps: one-way alert messages from each component to an SNMP manager such as Oracle Enterprise Manager, Oracle ASR, Nagios, Zabbix or SolarWinds.

Each component type is configured separately, and each one can send traps to several subscribers at the same time.

Each component sends its own traps to every subscriber you list EXADATA RACK Storage cellsCellCLI Β· ALTER CELL Database serversDBMCLI Β· ALTER DBSERVER ILOMILOM CLI or web interface SwitchesSwitch CLI SNMP traps UDP 162 Β· v2c / v3 Monitoring toolOEM, Zabbix, Nagios, SolarWinds Oracle ASR ManagerOpens Oracle SRs (type=ASR)
Component
Where You Configure SNMP
What It Reports
Storage cells
CellCLI (ALTER CELL)
Cell disk, flash, hardware and software alerts from Management Server (MS)
Database servers
DBMCLI (ALTER DBSERVER)
Hardware and OS-level alerts from the DB server MS
ILOM
ILOM CLI or web interface
Low-level hardware faults: power, fans, temperature
Network switches
Switch CLI
Port, link and switch health events

This guide focuses on storage cells and database servers, because those are the alerts most DBAs need first.

Prerequisites

Have these ready before you change anything:

  • SNMP manager details β€” the hostname or IP address and the trap port it listens on (usually UDP 162)
  • SNMP version β€” v1/v2c with a community string, or v3 with a username and passwords
  • Firewall rules that allow UDP traffic from the cells and database servers to the SNMP manager
  • Admin access β€” celladmin or root on storage cells, root or dbmadmin on database servers
  • Group files β€” cell_group and dbs_group if you plan to use dcli across many servers
  • The current SNMP settings, so you do not overwrite an existing subscriber such as Oracle ASR
Step-by-Step: Configure SNMP on Storage Cells

Step 1: Check the Current Settings

Log in to the cell and list the existing subscribers and notification settings:

storage cell
cellcli -e "LIST CELL ATTRIBUTES snmpSubscriber, notificationMethod, notificationPolicy"

Step 2: Add Your SNMP Manager as a Subscriber

storage cell
cellcli -e "ALTER CELL snmpSubscriber=((host='snmpmgr.example.com', port=162, community='public', type='v2c'))"
Watch out: ALTER CELL snmpSubscriber replaces the whole subscriber list. If an ASR subscriber already exists, include it again in the same command or you will silently remove it.

Example that keeps an existing ASR subscriber:

storage cell
cellcli -e "ALTER CELL snmpSubscriber=((host='asrmgr.example.com', port=162, community='public', type=ASR), (host='snmpmgr.example.com', port=162, community='public', type='v2c'))"

Step 3: Turn On SNMP Notifications

Choose how alerts are delivered and which severities are sent:

storage cell
cellcli -e "ALTER CELL notificationMethod='snmp,mail', notificationPolicy='critical,warning,clear'"

Use notificationMethod=' + snmp + ' if you do not use email alerts.

Step 4: Apply to All Cells at Once (Optional)

From a database server with SSH equivalence set up, check every cell first:

database server
dcli -g cell_group -l celladmin "cellcli -e LIST CELL ATTRIBUTES snmpSubscriber"

Then run the ALTER CELL command the same way. Quoting inside dcli can be tricky, so many admins put the command in a script and push it with dcli -x.

Step-by-Step: Configure SNMP on Database Servers

Database servers use DBMCLI, and the syntax mirrors CellCLI with DBSERVER in place of CELL.

Step 1: Check the Current Settings

database server
dbmcli -e "LIST DBSERVER ATTRIBUTES snmpSubscriber, notificationMethod, notificationPolicy"

Step 2: Add the Subscriber

Again, include any existing ASR entry in the same command:

database server
dbmcli -e "ALTER DBSERVER snmpSubscriber=((host='snmpmgr.example.com', port=162, community='public', type='v2c'))"

Step 3: Enable Notifications

database server
dbmcli -e "ALTER DBSERVER notificationMethod='snmp', notificationPolicy='critical,warning,clear'"

Step 4: Repeat on Every Database Server

Run the same commands on each database server, or push them with dcli -g dbs_group -l root.

SNMPv3 Setup for Secure Monitoring

SNMPv1 and v2c send the community string in plain text. Use SNMPv3 in production if your SNMP manager supports it, because it adds authentication and encryption.

Step 1: Set an SNMP Engine ID

This is needed once per cell, and the value must be unique:

storage cell
cellcli -e "ALTER CELL snmpEngineID='exacel01snmp'"

Step 2: Create an SNMPv3 User

Using * makes CellCLI prompt for each password, so it is not saved in your shell history:

CellCLI>
ALTER CELL snmpUser=((name='snmpadmin', authProtocol=SHA, authPassword=*, privProtocol=AES, privPassword=*))

Step 3: Point the Subscriber at That User

CellCLI>
ALTER CELL snmpSubscriber=((host='snmpmgr.example.com', port=162, snmpUser='snmpadmin', type=v3))

Step 4: Match the Settings on Your SNMP Manager

Configure the same user, engine ID and protocols on the SNMP manager so it can authenticate and decrypt the traps.

On database servers, run the same commands in DBMCLI with ALTER DBSERVER.
Testing and Verifying SNMP

Never assume alerts work until you have seen a test trap arrive.

Send a Test Trap from a Cell

storage cell
cellcli -e "ALTER CELL VALIDATE SNMP"

For an ASR subscriber, use ALTER CELL VALIDATE SNMP type=ASR.

Send a Test Trap from a Database Server

database server
dbmcli -e "ALTER DBSERVER VALIDATE SNMP"

Confirm It Arrived

Check your SNMP manager’s event console, or run snmptrapd in the foreground on a Linux test box to watch for the trap.

Load the Exadata MIB

Import the Exadata MIB into your SNMP manager so traps show readable names instead of raw OIDs. The cell alert MIB ships with the Exadata software on each cell, commonly as cell_alert.mib under /opt/oracle/cell/cellsrv/deploy/config/. The path can vary by release.

Troubleshooting Common Issues
Symptom
Likely Cause
Fix
No traps arrive at all
Firewall blocking UDP 162, or wrong host/port
Test reachability from the cell; check firewall rules and the subscriber's host and port
ASR stopped receiving alerts
ASR subscriber was overwritten when a new one was added
Re-run ALTER CELL snmpSubscriber listing both ASR and your new manager
Test trap works, real alerts don't
notificationMethod lacks snmp, or notificationPolicy is too narrow
Set notificationMethod='snmp' and include critical,warning,clear
SNMPv3 traps rejected
Engine ID, username or auth/priv protocols don't match
Make the user, protocols and engine ID identical on both sides
Traps show as unknown OIDs
Exadata MIB not loaded
Import the cell alert MIB into the SNMP manager
Only some cells send alerts
Config was applied to one cell only
Use dcli to list snmpSubscriber on all cells and fix the outliers

If alerts still fail, check that Management Server is running with LIST CELL ATTRIBUTES msStatus and review the MS log under the cell’s diagnostic directory.

Best Practices to Keep SNMP Alerts Healthy

  • Use SNMPv3 in production and avoid the default public community string on v1/v2c
  • Always list every subscriber in one ALTER command so you never drop ASR by accident
  • Keep the configuration identical across all cells and database servers, and check it with dcli after patching or adding hardware
  • Send critical, warning and clear so your monitoring tool can close alerts automatically when a problem clears
  • Configure ILOM SNMP too β€” some hardware faults surface there first
  • Re-test after every Exadata software update, since upgrades can change defaults
  • Document your SNMP settings β€” hosts, ports and users β€” in your runbook
Frequently Asked Questions

What port does Exadata use for SNMP traps?

UDP 162 by default. You can set a different port in the snmpSubscriber attribute.

Can I send Exadata alerts to more than one SNMP manager?

Yes. List several subscribers inside the same snmpSubscriber value, separated by commas.

What is the difference between SNMP and ASR on Exadata?

ASR (Auto Service Request) is an Oracle service that uses SNMP traps to open support requests with Oracle automatically. A regular SNMP subscriber sends the same alerts to your own monitoring tool.

Does configuring SNMP need a restart?

No. ALTER CELL and ALTER DBSERVER changes take effect immediately.

How do I remove an SNMP subscriber?

Run ALTER CELL snmpSubscriber=(...) again with only the subscribers you want to keep. To clear them all, use ALTER CELL snmpSubscriber=''.

Conclusion

Setting up SNMP on Oracle Exadata comes down to four steps: add your SNMP manager as a subscriber, enable SNMP notifications, secure it with SNMPv3, and confirm it with a test trap. Do this on every storage cell and database server, keep ASR in the subscriber list, and you will hear about hardware and storage problems before they become outages.

Recap: what to take away

  • Storage cells use CellCLI and database servers use DBMCLI; each must be configured separately
  • Add your SNMP manager with snmpSubscriber without overwriting existing subscribers such as ASR
  • Set notificationMethod to include snmp and send critical, warning and clear alerts
  • Use SNMPv3 with authentication and encryption in production
  • Test with VALIDATE SNMP after setup and after every patch or network change

Want more hands-on guides? KP Expert publishes practical, step-by-step guides for infrastructure and certification professionals. Explore KP Expert.

ORACLE EXADATA SERIES Published by KP Expert β†’
Recently Enrolled

Student enrolled in this course.

View course
Explore Courses

Latest from @kp__expert

Follow on Instagram
Loading Instagram posts...

AI Course Assistant

Share your details and goals to get the best course recommendations.

Recommended Courses

Select a course name to view full details.

Course Details
Enrollment & Contact
  • Review selected course and confirm your enrollment request.
  • Click checkout to move into the full payment process.
  • After payment submission, your enrollment is processed by our team.
Admissions Contact
Email: info@kpexpert.com
Phone: +91 92708 37105
Your submitted details
Name, email and phone will appear here.
Your request has been submitted successfully. Our team will contact you shortly.